LR Solid - Learn button has been pressed and board ready for learn cycle. Pressing OK button begins the learn cycle
[ ] Flashing - "Chasing Cursor" display is seen only during unlearned condition. Signifies motor activation and gate motion. Also confirms display segments are working at power up.
OP Solid - Open limit is activated
CL Solid - Close limit is activated
- - Solid - System in idle state (no motor activation) and no close or open limit activated. Also indicates BlueBUS devices detected and functioning.
AL Flashing - Hard shutdown is active and the audible alarm sounds. Display may be cleared by pressing Reset Button after obstruction is cleared from gate path.
E1 Flashing - BlueBUS scan error or no monitored safety devices detected. May be cleared by pressing the learn button if a monitored safety device is connected.
E2 Flashing - No actuator(s) sensed during first learning phase. Clear by ensuring actuator is plugged into board, then cycling power off then on.
E4 Flashing - Actuator encoder dropped out or failed during gate movement. Clear by pressing any button. Repeating error may indicate a faulty encoder or incorrect wiring.