GATE OPERATOR TYPE - Swing
GATE OPERATOR MODEL - 4300/4500
CONTROL BOARD - 1050
WHAT THE DISPLAY SHOWS - Enter is flashing
WHAT SHOULD BE CHECKED - Operator is in Learn Mode, verify that required number of entrapment sensors are present and that gate is 50% open
POSSIBLE CAUSE - Operators are shipped in learn mode
STEPS YOU CAN TAKE - Perform the learn procedure