GATE OPERATOR MODEL - 4300/4500
CONTROL BOARD - 1050
WHAT THE DISPLAY SHOWS - NA
WHAT SHOULD BE CHECKED - The gate operator has been installed on the side of the gate opposite of the programming.
POSSIBLE CAUSE - The operator needs to be set up for direction reversal
STEPS YOU CAN TAKE - Press OPEN and note if the gate actually opens. If it does not, and instead is traveling in a CLOSING direction follow the below steps to correct; (if already in learning mode, follow the below listed steps). 1. Press FUNCTION 2. Scroll through the options to reach ADVANCED SETTINGS 3. Press ENTER 4. Scroll through selection to reach DIRECTION OF MOTOR 5. Press ENTER 6. The direction arrows on the display begin to blink. 7. Choose the appropriate direction of travel 8. Press DISPLAY to return to the MAIN MENU 9. Press OPEN to verify that the gate now OPENS.